Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Electrical Engineering?

Answer Posted / thowsif_emerson

Electrical engineering, sometimes referred to as electrical
and electronic engineering, is a field of engineering that
deals with the study and application of electricity,
electronics and electromagnetism.

Is This Answer Correct ?    5 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Dear all, I want to use Induction motor to open and close a 1 ton door. How much power do I need. Thanks

1936


Iin ESP why positive is grounded ? why not negative ?

2758


it is possible to measurement of tension of slipring induction motor(SRIM)carbon brushes, any maesuring instruments are available in the markets.

2079


what is basic difference betmeen normal & flame proof motor??

2094


Best way to measure the Soil resistance of rocky soil, three probe method and four probe method

1992


What is Instantaneous Earth fault relay,how will work

2300


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2198


Why insulation level follows this order? transformer < bus bar < circuit breaker & Isolator < transmission line.

2184


What is meant by vector group

2628


What is the diff. between single compression and double compression gland

2052


When the relative speed between the magnetic fields of stator and rotor does is zero under steady state operation?

1329


what are the safety measures of induction motor?

2103


in the case of 6.6kv motor starter combination contain fuses on it VCB. but in 11KV motor starter combination Fuses are not using in it's VCB why?

2344


how make megger test for control cable like 12c x 1.5mm and what it apply voltage and test timing details.

2260


How is the connection of the tap changer on the HV side been made?

2037