What is Electrical Engineering?
Answer Posted / sam
a study to increasing knowledge on power generation
utilization selection of devices along with the
characteristic analyze of protons and nutros
| Is This Answer Correct ? | 1 Yes | 7 No |
Post New Answer View All Answers
what is the difference between surge protection capacitor and surge arrestor
What is the unit of attenuation?
In a carnot engine with an efficiency of 40%, the heat rejected to the sink at 27 C is 60 kJ, then the heat supplied in kJ to the engine by the sources is
In EDO ACBs what is a purpose of closing coil and motor, what is the operation of these devices are they inetconnected. means if we give supply to motor and by BCS we charge Closing coil,what exact is operation is and how it charge a spring of ACB. Sir if anybody has an wiring diagram please send me the link to operate and EDO breaker.
Why electrical power generation and transmission done in 3 phase system not more than 3 phase ?
what a function diesel generetaor turbo charger & turbo charger is more heated explain reason ?
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
What happens when two positively charged material is placed together?
Why do we need interlocking in a HT metering or Ring main unit switchgear?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
what is the purpose of slope in the differential relay?why we are using two slope?but in busbar differential we are using only one slope.why?
What is the formula to calculate the rating of power cable for three phase current.
send me any model test paper of clerical post of state bank of india.......
how to select energy meter? have any calculation?
what is the safety points of vaccum circuit breaker.