Answer Posted / thowsif_csm team_emerson
Transient Voltage Surge Suppressors(TVSS)
for equipment, panel and motor protection,UPS's
applications are specifically
designed to provide long life, even
under the most adverse over-voltage
conditions.
The purpose of a TVSS is to eliminate or reduce damage to
data processing equipment
and other critical equipment by limiting transient (surge)
voltages and currents (surges) on
electrical circuits. These transients or surges may come
from inside a facility, or may be
injected into a facility from the outside.
Is This Answer Correct ? | 15 Yes | 0 No |
Post New Answer View All Answers
the typical output of a solar cell is........
How to design pavement quality concrete by using C.R.C.P Method
what is mean by D.O. in distribution line poles?
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
Its possible to use 3core 2R of 240 sq.mm cable for 3phases & separely 50sq.mm 3core cable fully for Neutral for connection of PCC to MCC 3ph..4wire system?
When steam condenses and becomes water at the same temperature, the specific heat for the process in kJ/kg k is
What will be the diameter of pipe between conservation tank and transformer
where is the need for short circuit test for 3 see is required and why? can you explain in brief with application
what happens when dc generator coupled with cycle shaft.also explain what happens when its loaded
If we use 250A MCCB as a incomer in Control panel for a fault level of 50kA for one second ,assuming temperature rise from 85 Deg. to 100 Deg , Then what will be the Aluminium Bus-bar size for 250A MCCB? Explain in detail.
what is the question paper model for section engineer in RRB
Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this
Why r u using pf panel. what the uses
what is the need to express current and voltage in rms value? rms value is also called as effective value,what is effective value?
Why line VTG = √3 phase VTG in star? How?