why do we use magnetic contactors ?circuit breakers are not
enough?
Answer Posted / ashwani malhotra
The main function of magnetic contactor is to prevent
accidently operation after the power failure & again
recovery. Because as soon as power fail the holding coil
release the contacts and it will not operate untill someone
complete the hold circuit again .
| Is This Answer Correct ? | 24 Yes | 4 No |
Post New Answer View All Answers
I want to make street light with solar system ... What may I do for procedure and how much of estimation for each material ... If any one knows guide me and inform this id : aravindd7@gmail.com
armature is that part in which current is induced since in dc motor we supply current to the conductor so why we call it armature?
What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.
Where can i get practical knowledge of solar system?
Is it a better option to procure screw type air compressor rather than reciprocating air compressor?If so, what is the reason?How should we select an air compressor(100 CFM)? Please mention the important parameters of air compressor.
what are the installation procedure of high voltage power transformer,CT,CB&PT?
why current is constant on d.c?
how to enter inverter parameter? without manaual?
i have faced a problem in ro plant grunfos make bm30type pump it is 22kw pump. We start this pump using siemens 3rw 4423-ibc44, 30kw softstarter but this soft starter will frequently failier so we planed to change dol starter. So pls tell anybudy its possible or not.
For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?
What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.
What is the disadventage of gland earthing(power cable) if any. ?
What are the different losses In a de mac1une'! t.xplam
WHAT IS IEC? & WHAT IS BENEFIT TO PRODUCT FROM IEC?
List the disadvantages of constant k filters?