what is the CT of protection and CT of metering ? what is
class 5P10 & 5P20 and class PS ?

Answer Posted / arunmozhi

there are two type of ct in field,
1,protection CT
2,metering CT
protection CT; only for protect the equipment used to
relay based.

metering CT : this is only for showing the current in
ammeter .

In different type of class in CT 5p10,5p20 And ps it is
used for protection purpose only ,
5-acurancy class.
p- protection
10-10% error.
20-20% error.

ps class:it is calculate to the knee point voltage.

Is This Answer Correct ?    20 Yes 74 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Help need in transformer !? Hello Friends The parameters of 2300/230 v 50hz t/f is R1=0.286 ohm R`2=0.319 ohm Rc=240 ohm X1=0.73 ohm X`2=0.73 ohm Xm=49.2 ohm Secondary Load impedance ZL=0.387+J0.29 solve the exact equivalent circuit with normal voltage across primery.. I know every thing but i cant find CURRENT I1=? and I`2=? Please help me give solution or only Formula please please...

2535


How does zener phenomenon differ from avalanche breakdown?

710


Calculate torque developed by the 3-phase, 5 H.P., 4 pole induction motor runs at 1500 rpm A 23 N-m B 21 N-m C 10 N-m D 0 N-m

4370


How much should be the load percentage for 15kva Inverter and Iinut & I output load with Calculations

1587


sir please send me techinical questions for junior engineer posting in bangalore railway i am diploma holder

1559






in wind mill use 2100 kw asychronous generator ( induction generator ) rotor voltage : 3300,stator voltage : 690, rpm : 1511 type : MRL063E04 ' we check rotor resistance magger value found following. R-EARTH - 00 M.OHM,Y-EARTH-34 M.OHM,B-EARTH- 33M.OHM R-Y: 31 M.OHM, Y-B: 00 M.OHM,B-R :33 M.OHM HOW CAN I TAKE DECISION?pls ans. quickly

1887


What is transmittance?

650


CALCULATE THE TOTAL VOLTAGE DROP AND SELECT THE CABLE SIZE IN MM-SQARE FOR A PANEL-262KW AT 110 METER FROM THE SOURCE SUPPLY , SUPPLY VOLTAGE 240/415

2254


What is cathode ray oscilloscope (cro)?

686


how many safety really of DG sets.

1736


Can anyone provide with a SLD for HT panel installation for a 33KV line and distribution end has three 1.5MV transformers. Is it suitable to use OCB or VCB and also provide me the suitable rating and its connection diagram.

2899


I have a relay contact rated at 220v dc which is supplied with a 24vdc from the panel,for it to trip the dampers(24vdc).What if the application of the relay changes so that it should work at its rated 220vdc then will it work at 24vdc supply given or any other consideration needs to be taken .....

1662


I meggared my 2c*70 sq mm AL AR XLPE cable. its one end show 50 M ohm . is my cable is safe for laying. I have only one phase and neutral.

1353


what happens to the supply voltage if there is any change in frequency?

5692


Which type of DG need Netral Earthing?

4528