can any one list the class-a, class-b & class-c trips of
power generator?
Answer Posted / vinodh.t,sil,bellary
class-a
1.differential
2.over fluxing
3.residual over voltage
4.field failure
5.startup current
6.100% earth fault
7.low forward
claa-b
turbine trip+low forward
class-c
1.0ver frequency
2.under frequency
3.negative phase sequence
4.thermal over load
| Is This Answer Correct ? | 9 Yes | 3 No |
Post New Answer View All Answers
what is advertised hop count
any one please tell taht what type questions will be asked in BHEL interview, i am having interview on 24th Dec, please send this to mail pradeepsistam@yahoo.co.in
if any body have question paper of railway (section engineering),then plz send me .i will thank of him/her.
why we have to particulary use ACB for below ratings,even available of MCB,MCCB with that range ?
Tell me about ur past electrical maintanence job
A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.
A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE
I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.
What Maximam Gap Taibaar & Bush
What is difference between mcb and mccb.
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
i have to install a HT panel, what components, I have to use in this and what will the diagram of that diagram,please tell me each and everything.
what is allowed value of zero sequence impedancce of 6.6 kv nuetral earthing transformer ?what is the actual value
Explain about Leakage Test.
During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.