Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the inputs (drawings) we need to prepare loop
schematics??

Answer Posted / rajkumar

starting from your control desk terminal --- i/o details in
i/o cards of ur DCS or PLC ---terminal block details of i/o
rack cabinet----any marshalling cabinets in between that
terminal details---any interface in power room ie.. like
motor control panels---- then field junction box terminal
details---- then final field devices like txr or valve or
motor terminal details. Then you can finish your loop
drawing joining control room /i/o cabinet/marshalling
cabinet/ power interface room if exists/field jn box/field
device terminal.
I hope this will do!
Regards

Is This Answer Correct ?    8 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is zero and span ?

1653


What is Positive Calibration and Negative Calibration?

2237


how do i tune dearator pr control valve using PID. we set the set point is 0.6kg/cm2 now i want 0.5 to 0.7kg/cm2 limits so what should i give p,i,d values. then pls explain how do set pid values for control valve tuning?

1896


WHAT IS TMXT IN TEMPERATURE FOUNDATION FIELDBUS.

2304


Explain why plc require in analog input 4-20amp & 0-10 volt?

1084


With N nodes and B branches what will have a network ???

2018


How to calibrate RC Feeder system in thermal power station?,If any instrument available to calibrate it,ple inform me. make:stock,

3166


find the kp ki kd from the transper function G(S)=29.44s+04707/1.5349s2+s

1920


What is the use of control cable?

1138


1. For Steam drum level signal, why do we compensate with drum pressure signal? 2.For main steam Flow signal is comensated with main steam temperature signal and main steam pressure signal why?

2221


Give Detail information about plc,dcs,and scada system?

1724


What are different types of valves?

1311


few questions on RS 232,1 question on relationship of impedance and turns ratio, many questions on flowmeters

2025


what can of fault ofently come in vibration mesurement?

2132


What is the basic difference between Modbus and CAN Open Protocols

6427