WHERE IS THE LIGHTING ARRESTER SHOULD BE PLACED IN
DISTRIBUTION LINES?
Answer Posted / raghu
it should be placed on both sides of transformer and on pole structures and at the begining of distribution network
| Is This Answer Correct ? | 0 Yes | 3 No |
Post New Answer View All Answers
Refernce currents are to be generated using refernce cueernts how can this be done
In Indian Household, generally we receive 220V AC single phase supply. But AC has 2 phases, +ve & -ve. So in +ve half cycle current is flowing...so what happens in the -ve half cycle?? Please illustrate.
sir i applied for hpcl(electrical).i want to know from which subjects most of the technical que will b asked.and pattern of the written test.pls help me
Explain the operation of grid connected central solar inverter ?
Explain advantages of storage batteries
Why in power plant projects we see DOL starting method used for motors upto 160 kW instead of star delta method
Dear Mr B C pal...Can you plz. put some light on principle of operation of Z-Ct in conjunction to its use with 1Cx1000Sqmm HT Cables & Directional Ground Fault / Over Voltage Relays...Regd..Parag v K 9899115632
why do motors burn out? I understand why adding parallel loads to a power source means more current moves through the circuit, and can destroy circuit elements by overheating. What about when you have a vaccuum cleaner intake flush against a floor, a room fan sitting directly against a wall, or a power drill trying to drill through something too hard?
is it possible to have dc motors on single chip
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
at which voltage level arcing ground is occurs ??????????
The power supplied to a 33microF capacitor from a 120V, 60Hz source will be
On 400 amp factory load how kvarh capacitors provide
i want to run 11kv star connected motor in 6.6kv with delta connected throught inverter, is it possible?
If we want to change a contactor of faulty one what are the conditions want to fullfil