Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Supose we have one 220v A.C fan.if we provide 220v D.C what
will be happen?

Answer Posted / vishvesh

the Fan will not run, because principle and construction of
DC and AC motors are different from each other, AC motor
can not run on DC supply. and heating will produce in the
winding of the AC motor. if we supply it DC voltage.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is difference between slip rings and carbon burushes?

15085


I am doing apprenticeship training at HT switch yard in NLC. How can i get electrical c license. ??? What r the rules for getting it as an apprentice? ??

1839


I am inpecting a 10kVA UPS what tests should i do and should i observe?

2211


If you have an earth with pilecap then your resistance is really low. why and how?

1987


How to connect the chemical earthing and complete process tell me plz

1855


EXPLAIN METOD OF IMAGE OF TRANSMISSION LINE/ WHAT ARE ITS PRACTICAL APPLICATION?

1877


what is the acceptable limit value for Desolve Gas Analysis/

1974


How impulse levels are calculated that for 11kV impulse is 75kvp, for 24kV impulse is 125kvp ?

1998


How to calculate the electrical load for a standard telecom BTS shelter and choose the DG set capacity for the same load?

3177


I HAVE A INCOMING 100A MCCB TPN 25KA, CABLE LENGHT OF 80M 70MM CABLE SIZE FROM MAIN SUBBOARD TO NEW DB.BASE ON THE FAULT LEVEL SETTING OF 45KA.I WOULD LIKE TO FIND OUT 25KA ENOUGH KA. APPRECIATE IF SOMEBODY CAN ASSIST ME WITH FORMULA FOR THIS. FRM: JEFF

4026


describe the fully control circuit diagram of ac drives

1844


how to calculate the breaking capacity of different breakers.

2286


I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?

1864


What must be the minimum distance maintained between 2 Generators as per International standards?

2125


What is an alternator impedance value?

2848