Answer Posted / vishvesh
stepper motor is the electrical machine which act upon
input pulse applied to it. it is one type of sychronous
motor which runs in steps in either direction instead of
running in complete cycle.
so, in automation parts it is used.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
how much UPS neutral erath leakage current.
how can i find ct ratio of meter by seeing name plate of meter and how it should be used in MF calculation if it shows only-/1???
What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.
Explain thin film resistors and wire-wound resistors
what is destructive and non-destructive testing of welding
what could be the RMS value and average value of a 4 phase sine wave?
USE OF 8 WAY PAN ASSEMBLY
WHAT IS THE DIFFERENCE BETWEEN GENERAL INVERTER AND SOLOR INVERTER TELL ME PLZ
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
what is JE exam?
how to minimize earth resistance upto 2Ω, if the resistance is 6 Ω ?
When will you multiply and devide with derating factors to the actual value while sizing the cable?
if any body have question paper of railway (section engineering),then plz send me .i will thank of him/her.
What is accuracy of a measurement?