What type of isolation transformer used in UPS's??
It's Star-Delata Or Delata-Star????Why it is used????
Answer Posted / ravi
IT IS DELTA-STAR ONLY.
TO PROVIDE SINGLE PHASE POWER SUPPLY i.e PHASE TO NETURAL
CONNECTION IT IS USED AS A DELTA-STAR TRANSFORMER.
| Is This Answer Correct ? | 11 Yes | 9 No |
Post New Answer View All Answers
what is PDU in transformer?? which company manufacture??
An ISP is granted a block of addresses starting with 150.80.0.0/16. The ISP wants to distribute these blocks to 2600 customers as follows. a) 200 medium size businesses; each needs 16 addresses b) 400 small businesses; each needs 8 addresses c) 2000 households; each needs 4 addresses Design the subblocks and give the slash notation for each subblock. Find out how many addresses are still available after these allocations.
Explain the functioning of diode?
300m long and 30kw inductive loade 3phase supply how many size cable required
hi friends ,iam working as genset AVR service engineer in electrical field from past 2 yrs throughout india . i plan to shift in some other job without travelling in same field because i con't travel,i dont know what i do for that so please guide me what job is suited for me,how i can serch the job please anybody helpme iam totally confused
what is the grounding Calculation formula? spouse i want to provide grounding to 3phase 18kw motor or i want to provide ground to 3phase 10kva dry type transformere or you give me any exemple...... Thanks.
please explain how to do 'pole drop test' on generator?
What are two contours of nichols chart?
volts=230 c=10mf a=??
new 90kw motor installed so how I purchased cable ,fuse,etc please give me technic for cable selected why always capacitor delta connection
What is marx circuit?
why does make gain margin and phase margin on same plot.?
Dear friends, i would like to know that what is the exact function of 'exciter winding' & 'aux winding' in Alternator?
In EHV transmission line a neutral grounding reactor is often placed at neutral point of shunt reactors. What is the recommended protection for this neutral grounding reactor? Should I use a fast closing switch to bypass neutral grounding reactor when this protection operates?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?