Can anyone say that formula of Converting the Diff.
Pressure into Flow in Kg/Cm2 or any explaniation of Orifice
Plate, Beta Ratio , How to calculate
Answer Posted / rajkumar
The basic formulas for determining the flows are as follows:
V = k*sqrt(h/p)
Q = k*A*sqrt(h/p)
W = k*A*sqrt(h*p)
Where:
V = Velocity
Q = Volumetric flow rate
W = Mass flow rate
A = Cross-sectional area of the pipe
h = Differential pressure between points of measurement
ρ = the density of the flowing fluid
k = a constant that includes the ratio of cross-sectional
area of pipe to cross-sectional area of nozzle or other
restriction, units of measurement, correction factors, and
so on, depending on the specific type of head meter.
If you gather the outstanding data and use the above
mentioned formulas - you will be able to calculate your flow
rate.
| Is This Answer Correct ? | 9 Yes | 0 No |
Post New Answer View All Answers
Punj lloyd is coming in our Jadavpur Universtiy campus for campus placement. Please send me some hints about the writtend exam. My email id is subratafriends@gmail.com
1.what is controller proportional gain 2.what is the controller intergral action time. 3.A proportional plus derivative controller that has a proportional band of 20% and a derivative action time of 0.1 minutes. Construct the shape of the output waveform for the triangular input if the input rises and falls at the rate of 4 units per minute.
what is the protection system in solar turbine compressor
what is the working principal of pribe
what is dc moter.
What is Droop? What is Step/Gradient Limiter in Turbine Governor control?
which type of zones used for boiler? & why ?
key phaser where is use and work
Hi i am aneesh, done btech in applied electronics & instrumentatiin. And then i took mba in finance & marketing.After that i got placement in finance co and worked there for 3.5 yrs.Now i wanted to come back to engineering job.But without engg experience, i may not able to find an opening.i have done a course related to flow meters and ite calibrations. Kindly suggest where should i try to get a job?
plz send me general of ongc
Where are oxygen analysers installed in cfbc boilers? What are their usual readings?
Draw a P& ID showing – orifice flange, plate, dp transmitter, isolation & bypass valves and tubing.
What is the meaning of wet leg
send me HPCL paper
Emergency Shutdown Systems/ Plant Shutdown System.