how is working d.c amps meter?how to connect the dc ammeter
inthe circuite?
Answer Posted / ashwin
A DC ammeter is also known as moving coil or mc ammeter. For it to work connect it in series as current remains unchanged in series. So when the ammeter is connected in series the current flows through the coil in the presence of a magnetic field which causes a deflection.
for further clarification go to the link below:
http://en.wikipedia.org/wiki/Ammeter
| Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
what are the ''pitting rings''and how cn they be controlled in a series generator
why we use single core 630mm2 cable for transformer secondary side
What happens when two positively charged material is placed together?
How to calculate the Harmonics losses in terms of cost/unit.
Metal covered multiconductor cables shall employ a marker tape located within the cable running for its complete length in lieu of cable surface marking. Is it true or false?
How many double suspension hardware fittings are required on a double circuit transmission tower?
hai iam arunkumar. i have applied for an section enginner in rrb. i want lat 5 years solved question papers. if u have please sedn it to arun30682@gmail.com
what is the difference betweem star connected motor & delta connected motor?
IF DISTANCE IS 100METERS B/W AMP.METER AND CURRENT TRANSFORMER WHAT WILL BE AFFECT IN ACCURACY .METER CAN SHOWING ACCURATE CURRENT OR NOT IF NOT WHAT CAN I DO TO GET 100% ACCURACY.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
why h parameter are called as hybrid parameter?
How to calculate main incomer rating of APFC Panel ? Let's say i want to find main incomer for 11kV, 1000kVAR Panel.
Why it is possible to use PWM with a STATCOM and not with a conventional TCR based SVC
i want to learn control schedule for 11kv panel? can any one send the detailed control schedule?
What are the major reasons for balancing hydro-thermal mix?