Answer Posted / magi
Exact positioning of the valve stem
To minimise hysterisis
To linerise a nonlinear system
To use in place where actuator cant produce sufficien force
to move the valve stem
Is This Answer Correct ? | 17 Yes | 0 No |
Post New Answer View All Answers
There are two chlorination tonners both are connected to two pressure swithes and the pressure switch is connected to SOV which operates the valve to changeover the tonner selection i.e if pressure one tonner goes low the other tonner should come in line if it is inautomatic selection design a circuit using relays ?
Regarding , there is an air cooler which control the fans(50% of AV FANS) by temperature in outlet , and the louver of Air cooler is controlled by HIC from control system , So if on Air cooler we will consider 2 individual I/P converter or positioner?
i want formula for flow control.am doing project in flow control using orifice . i know value of the flow level(Q) . upstream(p1) pressure, orifice diameter(Do) , pipe diameter(Di) and oil viscosity(Vi) how can i calculate downstream pressure
Name different types of bourdon tubes.
What is the difference between mmwc and mmwg?
what is instrument philosophy
what are the definitions of input, output, command & signal according to instruments controlled by PLC using DCS System?
There are many type of control cable like pair,core,tried, What are defination each one
Introduce yourself which is not present in your biodata?
what is a good line as ic engineer as maintenance ,oc, project, calibration ,validation engineer?
What is shielding effect?
why would you like to join our company
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?
a flow transmitter [range-0-400mbar] connected in process line. please explain me how to calibrate the flow transmitter , & how to do static error