Answer Posted / aniruddh
Revese powe4r relay comes in action when the power flow
direction reverse when primemover faliar or lost of
exitation.
it use to prevent genrator for motoring acion.
| Is This Answer Correct ? | 4 Yes | 4 No |
Post New Answer View All Answers
What is the meaning of floating point earthing in battery backed systems ?
What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.
what are the standard IR values should be of R-E, Y-E, B-E, R-Y, Y-B, B-R of VCB in closed condition and in open condition for 500KVA & 1000KVA transformers. and what is the acceptable range when tested by 5000V megger.
How can we calculate the motor frame sizes?
If I bring a basic electric meter from the States and hook it up in Costa Rica in a development that has only one transformer for the 50 homes, will it still be accurate regarding the usage of kilowatt hours?
What is magneto on a gas generator. how it functions. its out put is d.c or a.c. how it can be checked for correct functioning
A parallel flow heat exchanger will perform better than a counter flow heat exchanger. State if the statement is true or false.
What is cross over distortion? How it can be eliminated?
What is icu and ics in Acb and how many time icu or ics passes from breaker?
Explain the purpose of inductor in an electric circuit?
I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?
sir& friends i want the collection of recent quetions asked in interview of top most companies please send me on my email san.jsr@hotmail.com
It is desired to flood light the front of a building 42 meters wide and 16 meters hig.Projectors of 30 degree beam spread and 1000 watt lamps giving 20 lumen/watt are availabl.If the desired level of illumination is 75 lumen/m and show a suitable scheme.Assume the cofficient of utilization, deprecitation factor and waste light factor are 0.4, 13 and 1.2 respectively.
I am B.E.electrical engineer having 7 years of experience in Transformer testing upto 315 MVA.I want to khow how I can get the 'Electrical Valuer' License.
What are test signals and their significance?