How to calculate cable sizes in sq.mm. with using motor KW?
Any formula there?

Answer Posted / a.bala

Hameent your statment is applicable for only small cable
size ( Up to 16 sq mm ) Please reff any one catalouge

Is This Answer Correct ?    50 Yes 32 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is creepage distance..... what will be the value for different voltage level

1603


Why in power plant projects we see DOL starting method used for motors upto 160 kW instead of star delta method

1479


explain supply side and demand side energy management with advantages & disadvantages

1796


Should power factor be low or high?

797


. What is Electrical Life & Mechanical Life of Circuit Breaker? 2. What is Electrial Life & Mechanical Life of Magnetic Contactor? 3. What is RCD, RCCB & RCBO? 4. What is the Between defferance of RCD, RCCB & RCBO?

2929






what is meant by residual over voltage & residual earth fault ?

8546


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1435


why a tester wont shock while testing the power in house

1430


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1636


I want formula to calculate cable size as per load given in length & amp. I searched many sites but didn't right answer. Please reply me asap.

1131


how to carried out tan delta test in 11 KV alternator ?

2622


what is sevice settings for mccb?How can be it setted?

1708


What is the importance of earthing?

759


Does the motor power displayed on the Motor name plate is the mechnical power motor delivers or it is consumed power from the system?

3567


How can two 3 phase transformers of same KVA and Voltage be connected in parallel?

1431