can a rotating machine give the DC output without commutator?
if yes, how? if no, why?
Answer Posted / s.sivaranjani
According faraday's law of electromagnetic induction
whenever there is a chanage in flux linked with the coil ,
it will be induced by an e.m.f (volatge).
Induced volatge will be of same type as that of source(i.e
alternating).
In DC machine(i.e) generator, the elecromagnetic poles are
generated with DC supply.
Dc machine consists of two main parts 1.stator 2.rotor
stator - stationary part consists of Poles.(north & south)
Rotor is a rotating one.also called as armature.
Rotor is fed by meachinal input i.e angular rotation.
Initially the rotor with armature coils do not carry any
current.
Because of the maechanical input the armature starts to
rotate at the constant magnetic field.
Therefore the armature experiences chnage in flux.
Hence an emf will be induced in the armature according to
faraday's law.
The generated emf is AC type. In order to make it
unidirectional (i.e DC) an arrangement is needed.
The arrangement is called Commutator.
Along with commuatator brush assembly is required to take
out the DC supply.
| Is This Answer Correct ? | 4 Yes | 3 No |
Post New Answer View All Answers
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
Explain (in simple ) - root mean square. whats its role in electrical fundamandal.where its used
What do you mean by Stimulastion Test in Diesel Genarator / Why & when it's conducted ?
STATE USE OF ARC RUNNERS & SPLITTERS ?
1. What is the exact formula for one weber? for example,(one ampere = one coulomb electron of electrons crossing a point of conductor at one second. i.e, 1A=1Q/1sec)
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
why do we lay up the core of a cable?
What is the difference between Encoder and Resolver?
How to calculate Temp from Resister from PT100 equation,
Damping resistor provided in open delta (tartiary) winding of a measuring PT at the incoming of a MV inverter drive panel is getting heated up. Can any body explain the reasons and suggest the remedy?
why on axial hitting up of air blast on hydrogen produced in oil circuit breaker,temperature rises of the core of the arc?
8. A DYNAMOMETER TYPE WATTMETER RESPONDS TO THE.......
How the PF control while running DG set with load
Readings of ER300P Trivector meter
11KV AND 22KV NETWORK KW CAPACITY IN RING AND RADIAL?