Why electricity is generated and transmitted at the values
of multiples of 11?
Answer Posted / ishaan
The electricity is generated and transmitted at the values
of multiples of 11 because the value of form factor is 1.1
for sinusoidal waves, we generally incoorporate sine wave,
cose wave for electrical signals and at this value of form
factor, the efficiency of any electrical equipment is
maximum. More precisely we would say these are the
multiples of 1.1 like 6.6 etc.
| Is This Answer Correct ? | 11 Yes | 2 No |
Post New Answer View All Answers
1.25 kg of hydrogen are burnt with stiochiometric air, the mass of air in kg required is
why should small green grass ans small plant should not be there inside the transformer Yard in the factories
Distinguish between nuclear power station with thermal power station for initial cost, starting period, cleanliness, and transportation of fuel
What is the maximum number of swithes that can be connected in series up to down stream point in an LV Distribution system?
The 3 phase 400 hp 440 volt slip ring induction motor do not take one phase amps why ? The motor is running good condition
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
HOW DO I CALCULATE THE SETTINGS FOR THE DIFFERENTIAL PROTECTION OF A 12kV/6.6kV, 6MVA,DYN11 XMER WITH PRIMARY SIDE CTR 400/1 AND SEC SIDE CTR 600/1?
IN dc capacitive reactance is??
what is the main difference between power devices and signal devices
How to calculate energy stored in an inductance?
Formulae for calculating the transmission line losses for different voltage levels
why 15 kw motor winding resistance is low then 5 kw motor winding resistance?
HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.
What is dc current source?
how to test reverse power trip?