Answer Posted / y.vidya sagar
AVR is Automatic Voltage Regulator and is essentially an
autotransformer and has two windings in it namely exciting
winding and series winding.
Exciting windimg is connected in parallel with the circuit
and the series winding is in series with the circuit.
series winding has tappings on it variation of which leads
to variation in the voltage at the secondary side.
It can boost aswellas buck the voltage depending on the
connection of the reversing switch that connects the series
winding to the ckt.
Is This Answer Correct ? | 2 Yes | 2 No |
Post New Answer View All Answers
what is sevice settings for mccb?How can be it setted?
What are the various types of BUSBAR Schemes? explain each
how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets
state the working of discharge lamp?
why lightning arrestor are made in two stack of insulator but why not cvt
If UG power cable both ends are to be earthed or what? If not why?
how can i find ct ratio of meter by seeing name plate of meter and how it should be used in MF calculation if it shows only-/1???
My question is abt backlog.I had dropped one subject in my second year, and completed this subject in the 3rd attempt, so how many backlogs i have got?1 or 3?plz sujjest the answer as soon as possible
working principle a.v.r. ?
how to calculate power consumption in slip ring motor at different step
How to calculate no of EARTH PIT? Describe the formula as per IS standard?
Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing
how technical is calculated in 11kv line and lt line
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
There are different classes of protections in power plants.class a,b,c are clear..is there any class d and e r there..and elaborate class b protection.