Answer Posted / umar
220V/50Hz system is used in india and Pakistan while
120V/60Hz is used in KSA and USA.
The advantage of 120V over 220V is human safety factor i.e.
less insulation required and less danger of electric shock
but it has the disadvantage that the initial cost increases.
Also size of electric equipment reduces with increase in
frequency such transformers etc.
| Is This Answer Correct ? | 50 Yes | 7 No |
Post New Answer View All Answers
Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing
How to design inductive load for 3 phase 440v and maximum 5 amps for star or delta? Can we use a 15kW, 1450rpm motor for 15kW, 960rpm apllication?If yes.how......n.if thesame motor used what`s it`s sideeefect.
What is superposition theorem?
Please tell me the power flow from pmg to main rotor of an alternator (Including AVR unit)?
how electrical earthing maintenance done in industry?
Difference between shunt, PMG and AREP excitation. Which is the most reliable between PMG and AREP.
WHat is the general checks required for Dry type transformers
Explain the different methods used in the choice of rotor slots for reduction of harmonic torques in an induction motor.
A 11KV, 1200 A breaker combination fixed in a cubicle for HT motor.Is normally for 11 KV motor fuse is using? if Yes, What range fuse is required?
What are the three types of compensators?
I want to put this query to SENIOR & EXPERIENCED ELECTRICAL ENGINEERS. 1)I want to know about the control circuit diagrams for control panels. I found it difficult to understand. Is there ant booklet through which we can learn the circuit diagrams? 2)I want to learn about conduiting, laying cables, preparing cable schedules and various techniques which is the part of building infrastucture(construction field). I don't have any experience in this area. I have experience in control panels only. that's why i am not getting any opening in building infrastucture (construction field).Can I get the job in this field as Trainee Engineer? How to enter this field? I need job in PUNE
Can anyone explain me about the RLC based Impulse high voltage generator and how to and operation of Series resonant High voltage reactor...?
why we use four type of phase angle difference between pimary & secondry winding of a transformer & where we use them?
Dear sir, In our plant have Station Transformer having capacity,i want to know, why LV side 40 - 40MVA is given? & how we can get 6.3 KV supply from tertiary(i.e. Open delta connection), Vector Group YNyn0 - yn0 +d MVA Rating 80MVA / 40 - 40MVA + 26.7MVA Voltage rating 420 (Tap range +6,to -10)81.25% /11.5KV - 11.5KV +6.3KV
why Current is lead 90 degree and voltage is lag 90 degree in a capacitor.? why Current is lag 90 degree and voltage is lead 90 degree in an inductor.?