Explain the working principle of servomotor
Answer Posted / santosh awasiya
servo motor is constent speed motor by using n-coder
| Is This Answer Correct ? | 86 Yes | 68 No |
Post New Answer View All Answers
how wecalculate breaking capcity of acb mcb mccb .explain with example
The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.
What are the three constants associated with a steady state error?
what is the most permissible winding temp when we conducting a generator load test?(condition no load)
any application of back emf
why we used dc supply for field in dg set
The simple way of finding the leakage quantity and % in compressed air distribution system
1. for eg, capacitor is used for many purposes(it act as filter, oscillator, bypass capacitor, memory storage etc...) 2. Please tell me some example circuits for different uses of capacitor( whenever and whereever and however we used capacitor as a filter, oscillator tuning etc..) 3. similarly for inductor and resistors(it act as what?) and when and how we want to act as like that?, and how we can used these components depends upon our requirments with example circuits and explanation? design to act as these components depends
what are factors comes under relay setting (distance relay 7sa52) under OPEN DELTA VTs connection??
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
who invented active elements? plz give me the complte details of active elements...
Is there a possibility to use such a treshold voltage for the NMOS part of a CMOS circuit that during the switching it will start conducting only after the PMOS part will be already closed, by this eliminating the leakedge current? Please note, I'm not asking about the well bias in standby mode, but about the "antileakedge" measures during normal operation.
write encoder 17 pins details? pin a;b+, pin b;w+,..pin s & t. what is the meaning of b+, w+? explain;
I Need standard operation procedure(SOP)for 500kva Oil type transformer oil filtration & Procedure for IR value checking.
Is it possible to use a S1 duty class motor for crane application (S4)? If not, why?