What is the difference between HMI and SCADA and MMI
Answer Posted / gyani
It was first MMI man machine interface and was objected by
US Girls engineer/operator,so changed to HMI human machine
inteface= difference zero. SCADA & HMI having more or less
equal features.company's choice too to make separate.
| Is This Answer Correct ? | 7 Yes | 2 No |
Post New Answer View All Answers
model question paper of instrumentation for Jindal GET 2010.plz reply sudhanshukumar08@yahoo.com
Specify ideal accuracy of flow element like orifice plate, Ventury, Annubar. Ultrasonic flow meter etc.
what is a half wave, full wave, and bridge rectifer.
Displace type LT to be calibrated in workshop, wt. 40, dia- 60 mm, density- 0.8kg/cm3.
Which type of diagphram use in costic line,DM water line,natural gas line,oil line?
How to Calibrate Flow Switch in field
Explain why plc require in analog input 4-20amp & 0-10 volt?
WHAT IS THE DIFF. BETWEEN SKIN TEMPERATURE AND PASSES TEMPERATURE..?
what is the calibration procedure for transweigh make weigh feeder?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
what is droop in governer ,type of droop ,how it work
Emergency Shutdown Systems/ Plant Shutdown System.
Can any one tell me what type of question asked for instrumentation and control interview panel??? pls mail ramashankar.goel@gmail.com
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
plz tell me clearly about PID.."when v have to change I value,D value,GAIN??