Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why all voltage levels are the multiples of 11KV?

Answer Posted / khongserbu

since all the voltage generation are in average and we use
rms quantities for computation. so we need to convert the
average to rms simply by multiplying the form factor 1.11.
thats how the voltage levels are in the multiple of 11.

So stop fighting both of u

Dr. khongserbu
university of lungzor
poktor
Chazzam

Is This Answer Correct ?    45 Yes 26 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible

1985


how slip power recovery system work

3027


what is the minimum requirement gigaohms for the insulation test using 5kv in 300mm xlpe cable

1981


what is kvarh? Please define it With calculation General motors ?

1168


how could we know the size of cable by physical view?

1627


why any centrifugal blower draw more current in starting. consider id fan and fd fan?

1860


What is conventional thermal current (Ith)

4444


what is induction furnance? how many phase supply given io its coil for 15 or 20 ton furnance?

3416


tan delta equation test on alternators

2220


Is it advantages of having star-delta vfd than normal star vfd , if yes why?

2261


What is the difference between UPS & inverter ? which UPS is better and whos got the edge ? what is the difference between & inverter ? which UPS is better and whos got the edge 12 V , 24 V , 36 V etc what are the advantages of 12 V, 24 V , 36 V etc and what are the disadvantages of 12 V, 24 V, 36 V etc thanks

1906


How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?

2759


how net resistance islow in star connection and viseversa in delta connection...? if anybody could explain in detail it wud be helpful.

1608


Why does the rotor rotate?

2278


how to calculate the mesh earth network resistance in such substation, is there any recommended resistance values with references , thanks!

2336