Answer Posted / abbas haruna
THE TWO ARE ALL POWER, BUT THE MAJOR DIFFERENCE IS KW IS
ACTIVE POWER WHILE KVA IS APPARENT POWER. THE FORMER IS
RATED IN WATTS WHILE THE LATTER IS IN VOLTAMPERES
| Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
in my working site. momentary jerck in electrical supply ocurred frequently which cause of multiple losses in our electrical equipements. how can we protect our electrical machines and equipements in this situation.
How earthing/grounding done in aeroplanes and ships.
for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?
in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
What is the method for testing the differential protection stabilty in generator? When the time of starting What will happen if differentail protection connection wrong means?
What types of CMOS memories have you designed? What were their size? Speed? Configuration Process technology?
What is relation between transmission lines & Communication lines ?
Define characteristics impedance?
While performing stability test of differintial cts how to know the voltage and current on both side of the transformer?
what are the tests comes under the type test, what tests comes under routine tests.
A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE
How many energy meters can be connected on a 15VA Voltage transformer. please send a calculation sheet.
How we calculate the Multiplying Factor of Kwh meter for 3 phase alternator.
Explain RLC circuit?