why screw pumps are used instead of centifugal pump?
Answer Posted / dhruv
compact design of screw pump can result in dishcrge
pressure at low speed while in centrifugal comp.if we want
the same pressure then hig sppe/big casing/big
impeller/more vibration/big motor-so to ever come all these
screw is better then centi pump-screw is able to pump
viscous material also while centrifugal-willlbe less
eficiency.
| Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
In which process internal energy remains constant ?
what is the function of platern water wall in a boiler? and difference between with ordinary water wall?
Is the unit and normal value fuel ratio of an average diesel engine?
What is the normal vacuum pressure in a steam turbine atmospheric condenser?
AS I AM BEING IN PLANT ENGINEERING & MAINTENANCE DEPARTMENT I WANT ANY BOOKS RELATED TO MAINTENANCE CAN YOU GUIDE ME THE AUTHOR.
hello i have a problem !!!! i am studying gait analysis"human walking; and i had only single camera"sony 25 frames/s" and 2 separated force plates, and there is no synchronization between the camera and the force plates!. i wrote a matlab program to calculate joints moment(sagital) using inverse dynamics methode. and there is a problem with the output data!! can you help me.
in the design of a rack and pinion with the pinion having a pitch of 4in and a teeth number of 45,how many teeth should a rack of length 196.850in have
Low water in boiler drum is unsafe because it may result in overheating of water tubes in furnace. Why it is unsafe to have high water condition in boiler drum ?
What is the mathed of maintain oxizen level in a air tite A/c room.
How fuel oil consumed by medium engine?
What is 1810 stainless steel?
Define railroad track ballast?
Define convection.
• Why not 4 phase & 5 phase
What is the cause of pressure drop in a centrifugal