why DC current not used in Transformer action?
Answer Posted / mahesh rathod
in the case of DC the flux produced is steady,which doesn't
induce any emf in the primary& secondary wdgs
in the absence of prim emf,the wdg draws high magnetising
current from the source which burnts the prim wdg.
| Is This Answer Correct ? | 2 Yes | 2 No |
Post New Answer View All Answers
Define corner frequency?
State and define norton’s theorem?
How to calculate the fuse rating depend upon the DC circuit?
what is rating boiler
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
WHAT IS AIR GAP VALUE IN MM FOR A 11KV BUSHING OF 11KV/440V DISTRIBUTION TRANSFORMER. AND AIR GAP VALUE OF 25 KV BUSHING OF AT TRANSFORMER OF 25 KV TRACTION. WHAT IS THE CALCULATION FOR THE AIR GAP PERMITTED FOR BUSHINGS AT DIFFERENT VOLTAGES.
Vaccum circuit breaker
I have a 380 KVA DG set. How can i find out 1. My Fuel Consumption per hr ? 2. Electricity produced in 1 Hr. ? 3. If load varies then how does it affect fuel consumption & electricity produced ? Please HELP !!! Really need an answer.
I am interested to know what does 15 KVA DG set actually means? If I dont know the DG rating, is it possible to identify KW by simply knowing the diesel consumption?
how many single tension hardware are required on a double circuit transmission tower?
What is essential to prove safe isolation of electrical circuit?
plz send me HPCL apptitude paper.. maulik_elect@yahoo.co.in
what is the difference b/w ATS and HTS?
whats the differece between Exd and Exe
How to calculate fault level of 11 KV system