AC current is flowing in a wire in your home how can you
measure it(name of the instrument)
Answer Posted / bhanu pratap
tong tester and clamp on meter are the same . tong tester is
the technical name and clampon meter is the name used by
line mans
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
(1)Can earth and be conected together (2) what is the diferent between earth & neutral
mccb service sittings be done?
Dear All we are having a problem in G120 BOP showing alarm A0503, F0052, F0060 we can not remove fault alarm ,Please any body help us. kowsar
In single phase capacitor motor, if the motor rotate reverse direction then how much power will be consumed by the motor and why?
What is given by the definition in BIL IMP/PF = 950/395 kV. This was found in a name plate of a power transformer.
how to Select Lighting arrester? What r the parameters to be considered for the selection of Lighting arrester ?
What is ideal IR values for ground and neutral.
Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?
What will be the size of copper cable (each for 3 phase and 1 neutral) from Service connection Kit-Kat to Panel Board (i.e. to main switch) for a 6 pole 3-phase AC induction motor of 200 H.P. capacity? Amp-255 A, Frequency:- 1450 rpm.
what happen if the load connected to the induction motor is taken away? the same question for synchoronous generator in synch i think that the the exitation voltage will appear on the terminal only if so plz answer me
What is inductance?
how can maintain the power factor and why and this is how do work tell us
there are cam operated switches - why we call cam operated , What is cam ?
In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.
In which of the following case, the rotating magnetic field is reversed? A regenerative breaking B plugging C dynamic breaking D forward motoring