what is the primary sensing element in flow or pressureand
level transmitter?
Answer Posted / ravi
diaphragm can be used to sense pressure, by sensing this
pressre we can measure the level of the tank. orifice plate
is the priming sensing element for flow. diaphragm based
differential pressue transmitter is there to sense pressure
and this presssure as primary data, we can calculate the
level of the same tank to which this PT is connected.
| Is This Answer Correct ? | 24 Yes | 3 No |
Post New Answer View All Answers
how to measure draft pressure in transmitter pl. give its single line digram
how pressure transmitter work, what is its principal to measure and how its generate signal. for pressure transmitterinstallation which precautions must be taken ??
what is function of SCADA , and how is it work, explain with difination
what is the different between deflection type measurement and null type measurement in RTD?
1- Explain about HPM 2- What is the FSC and explain the configuration of FSC 3- explain the complete loop of vibration, how it works (field to control room) 4- What is the use of proxymitter? 5- During job your partner effected with H2S then what you have to do. 6- what type of gland packing uses when valve glind is leaking.
in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.
how do we commission inergen system?
How does a single acting, spring return ball valve actually work? Does it require continuous air supply?
What is Droop? What is Step/Gradient Limiter in Turbine Governor control?
what is dc moter.
what is the field bus calble ? what are diffrences in orang colur cable and black coular calble ?
Hi i am aneesh, done btech in applied electronics & instrumentatiin. And then i took mba in finance & marketing.After that i got placement in finance co and worked there for 3.5 yrs.Now i wanted to come back to engineering job.But without engg experience, i may not able to find an opening.i have done a course related to flow meters and ite calibrations. Kindly suggest where should i try to get a job?
sir i m preparing for BARC but i am not getting any papers to prepare for this exam so please send me some sample papers to my i.d for the preparation of barc.
POSSITIVE PULSE IS APPLIED TO AN INVERTER INPUT.THE TIME FROM THE LEADING EDGE OF THE INPUT TO THE LEADING EDGE OF THE OUTPUT IS 10 ns. THE TIME FROM THE TRAILING EDGE OF THE INPUT TO THE TRYLING EDGE OF THE OUTPUT IS 8 ns. WHAT ARE THE VALUES OF tPLH and tPHL?
how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?