Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the types of transformers

Answer Posted / saurabh gupta

Types of transformers:
a. Distribution
b. Power
c. Control
d. Auto
e. Isolation
f. Instrument potential
g. Instrument current

Is This Answer Correct ?    7 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why we are use dol starter up to 10 hp

1376


What si the d/f b/w KVA & KWH, kvarh & kvar, kwh & kvar phase voltage & line voltage

6167


Why insulation level follows this order? transformer < bus bar < circuit breaker & Isolator < transmission line.

2145


How to calculate cable rating for 3 phase supply?

2189


How many VSC based HVDC are there in India and the world

2238


While testing LA mast,What are the parameter limits ?

1909


How seriving & testing of the HT & LT breakers are done. What are the standard Ir values on which we can come to know the test is passed or failed?

2053


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

1985


r we are using in gas turbine mark (5) frame (6) (made in india Bhel 1997) Ā

1718


how to fit 3 HP crompton gear motor with conveyor with the use of staring delta starter or ordinary starter?

2019


If SFU is Switch Fuse Unit, What is the expansion for FSHF in Electrical Engineering?

2596


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1801


What is the most important precaution in any experiment with d.c. Shunt motor?

1268


apti mainly on logical reasoning, verbal and non-verbal ability (70 percent) and remaining technical. I was in ee but technical had mech ques like on turbines and welding.

2186


What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?

2043