Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the function of Choke?

Answer Posted / sridhar

It induces very High Voltage when switch is made On and the
Tube light ignites to establish flow of Electron from one
side to other and vice versa. After tube light glows it
reduces the voltage between the terminals of the tube
lights which is sufficient to keep it glowing.

Is This Answer Correct ?    34 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How line capacitance & line inductance varies with increase in height tower.

2338


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2132


why Induction Generators are not "Black start" ? and apart from WTGs where this types of generator are generally used?

2657


Hi Friend I am used multimeter to measure the voltage between R Phase(SS1) to R Phase(SS2). In SS1 is connected with UPS loads. But I am getting voltage between these 2 R Phases. Please give some idea friend

2101


What are diffrent type of road taxes?

2031


what is servo motor and how it works?

2296


What do you mean by ratio correction factor of instrument transformer?

1181


What are the application of filter?

1068


What is the effect on 3phase induction motor if current setting knob of DOL kept at minimum current?

3746


what are the difference between AC lamp and DC lamp

2096


What is a dc motor?

1183


why the India electrical supply transmission loss is high when compare to us

1988


How to check the Bushings of the transformer?

1816


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

2458


What happen when neutral point connected to core balance current transformer? (Neutral point of an alternator of a 180KVA DG. Neutral point connected to CBCT means enter to the CBCT)

2299