Answer Posted / msalam_shahin
Though Transformer is an inductive circuit so it can act as
a low pass filter.......
But if the transformer's supply frequency is higher then
the transformer then the paper insulation and di-electric
oil act as capacitor. Then the combined effect of
transformer's inductance and capacitance act as a band pass
filter.....
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
LET ME NOW MORE ABOUT icu and ics for circuit breaker. how we calculate the rating of circuit breaker and i c u and ics values
What is the feedback in the control system?
1.WHAT IS A SMART CAPABLE DB ( DISTRIBUTION BOX) ? 2. HOW TO DECIDE THE TYPE OF DB TO BE USED ( RECESSED/ PLUG TYPE/ SMART ETC ETC? 3. WHAT IS MILLENEUM BUS BAR USED IN DB? 4.DIFFERENTIATE MCCB AND MCB.
What is meant by reverse polarity and how it can be fixed?
What are the Formula of computing Back up Time of 500kVA UPS with 4 Battery Banks, each bank composed of 43 pcs of Batteries 12V150Ah. How to compute the Back up Time of UPS? We have also 3X500kVA UPS running in Parallel same composition as I write above.
How to Calculate Current Rating of SDFU (Switch Disconnector Fuse unit) for Protectionof Capacitor Bank connected to Busbar of 800Amp,in LV side of 11/0.433KV, 250KVA Transformer?
hello friend i wish to study a course related to the electrical construction, controlling and monitoring , which course i want to study? pls give me the name of institute?
What is the function of electron gun used in crt?
What is meant by Im=30mA@Vk/2. How to know the kee point voltage for CT design
what kinds of Transformer oil grade is better for power transformer ?
If two Transformers are connected in parallel having impedance of 50KA in both transformers will the impedance increase or decrease after connecting transformers in parallel?
A powerplant has 8 gensets operating in grid parallel mode. In one genset sometimes there is pf variation and kvar variation. The plant operates in pf mode. When this variation is observed the load is stable, voltage is also stable, freq and genset speed is also stable. How will you check the functioning of pf card. What shall be the ideal output vdc of the pfc, from there it is input to AVR?
Advantages/Disadvantages of earthing of neutral bus on MSB instead of separate neutral earthing for transformer/DG sets feeding to MSB
how to measure the transformer resistance values(dyn11)?and howmuch the minimum value?
What is T’Q and X’Q and X’D ? and what is saturated as well as unsaturated ?