Answer Posted / patel ronak r
INDUCTION MOTOR IS USED FOR HEAVY RESISTANCE MACHINERY.
LIKE CENTRIFUGAL PUMP,HIGH GEAR PUMP, CRUSHER
PULVERISER,AND SOME HEAVY ROTATING PARTS LIKES IN CHEMICAL
COMPANY MANY OF THE BIG RACTOR SO IT'S AGITATOR ROTATING
THIS TYPE OF INDUCTION MOTOR USED. BECAUSE IT'S EFFIENCY IS
VERY HIGH.AND IT'S LOSSES LOW.RESISTANCE OF INDUCTION MOTOR
IS VERY HIGH.
| Is This Answer Correct ? | 40 Yes | 17 No |
Post New Answer View All Answers
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
Why we use ups battery and dsdb battery in thermal power plant
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
Whether amorphous core transformer is available in India?.If available then up to what rating of voltage and KVA?.
hi everybody how to design string combiner box (scb) internal parameters like bus bar and spd (surge protection device and fuse which place to set that,and also bus bar one particular cross sectional how much heat generated and how much power loss tell me Clearly and briefly
1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to reconfirm its base capacity.
Define relative stability.
how to test reverse power trip?
Do u know any one? how to find out in motor rated amps? formula?
we have consol make 3 phase servo stabilizer for cnc m/c. while installing the earth neutral voltage is 1.7 volts at stbilizer off condition and when stabilizer get on en voltage reaches 4.8 volts (new earthing is done and neutral is helthy condition all phase to neutral volts 440,442,441 v)why this happen.solution for cause.
Testing report of Earthing of 3.15 MVa PTR.
What are the ratings of VCB, MCB, MCCB, SF6, ACB, and OCB?
We have studied about many techniques for finding the stability of system, ROOT LOCUS, ROUTH, BODE PLOT, POLER PLOT etc. In these which is used where. what are the difference among them... PLZ tell me.......
how to avoid electrical shock how capacitor store charges wat are the speed control of induction motors state faradays law flemings left hand rule what is rotary converter wat is transmission and distribution what are the sources of energy abrevation of acb,vcb,sf6,igbt what is output equation of transformer which test copper iron and iron loss are calculated what is eddy current draw a single line diagram (10 marks) draw direct online starter(10 marks)
How To Convert Apparent Into Real Power Without Knowing Reactive Power?