Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Types of 132KV and 222 KV protection.

Answer Posted / sumit mishra from areva t&

Each & every switchyard are having set of equipment which
are required for tranmission/distribution of electricity.

So we cn classify the protection as..

Distance or line protection
Tranformer protection
Bus bar protection
Back up protection(O/C & E/F)etc...


Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT IS DEAD END IN PROTECTION?

2682


when we gave dc supply to 220v dc motor its rpm is 1200. then we gave 180v. how many rpm of its motor. gave answer with calculation at my ID.... ravizak@ymail.com

2410


Why let through energy not considered for ACB breaker while cable sizing?

2473


why high speed tripping relay is used in protection circuit why not normal relay

1574


why in the three pin plug all 3 pins are cutted ?

2071


Why reactive power is needed in a power system? How is it being absorbed or delivered by alternators? For reactive power control we are changing excitation but reactive power absorbing or delivering related to stator. How these two are interlinked? i want a detailed explanation with necessary expressions and figures?

1965


what is kvarh? Please define it With calculation General motors ?

1229


why on delay timer used for fully automatic star delta starter?

1747


what is the Transformer Impedence?How can calculate?

2166


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1983


WHY CBCT USE ONLY IN Y PHASE NOT OTHER PHASES

2161


what is the use of vcb & isolator in substation?

2462


What is reactive power and where it is used.

1754


how to calculate distance between busbar supporters for LT panel, what are the factors influencing in this design

5393


How do we find the rating of a transformer, if it got burnt badly.

1613