Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

if we convert ampers into kwh or mwh ,which one formula use
by us,pls tell me?

Answer Posted / omar aziz

Look , Always try to understand what quantities you have
and their significance. This will help you derive other
quantities yourself using the first principles. Lets derive
KWhr from current I !

Firstly you need to know the voltage at which this current
is drawn from its supply. V

Once you have this info you can find the power flow = V x I
this is in W if you use SI units throughout

Divide it by 1000 to get KW

KWh = unit of energy therfore its Power x time

Now how long would your current be drawn for. say its a fan
drawing 2 Amps and you keep it on for 5 hrs at 240V

(240V x 2A x 5hr)/1000 = 2.4 KWhr

Is This Answer Correct ?    16 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are the parameters plays a major role in Potential transformer Burden calculation??

2281


Ceiling Fan and Storage type water heater. Discuss

2021


Please brief working principle & construction of permanent magnet AC Servo motor

2289


What is the dc grounding system and what is diff between AC/DC grounding system?

2172


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2204


what r the checklist while installing a 380 kva DG set

3852


What is the ratio of true power to apparent power in an ac circuit?

1190


WHAT IS THE WINDING PROCEDURE OF ELECTRICAL MOTOR

4041


what happens in the short circuited secondary transformer,if the resistance of the short circuit is increased gradually?

2431


how brushed dc motor operating ?

1938


PLEASE TELL ME ABOUT QUESTION PAPER OF UPCL ENTERENCE EXAM.

8059


how does a liquid starter reduce the starting currents?

2197


What Is Sampling?

1255


What's mean HVF & HAF in Vacuum Circuit Breaker?

5415


Either It Possible a dc Motor to Run On Ac Drive [ Ex : ACS 800 , Yaskawa F7 ] If it is Possible How Pls Inform Me dinesh_elect_eng@yahoo.com

2045