is it possible to convert electrical energy to light energy
for transmission purposes?

Answer Posted / sreeni

it s possible first we have to convert AC to DC then that
dc can be converted into light form and then transmitted
through OFC cable then again we need one convertor that is
DC to AC convertor .... but one thing we don t have any
instrument to convert direct AC to LIGHT form ... and also
highly impossible to transmite ....

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

can we use engine degreaser for electrical motors?

1303


There are different classes of protections in power plants.class a,b,c are clear..is there any class d and e r there..and elaborate class b protection.

1636


HOE WE CAN IMPROOVE BY USE OF CAPACITOR

1520


What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?

1347


when we have to use UPF wattmeter and LPF wattmeter? what is the difference between UPF and LPF wattmeter in terms of construction?

1931






How does the phase sequence controller works, how it identifies the phases? confirm working principle

1617


what is the main function of capacitors in mccs.

1272


As an electrical engineer what are the responsibilities which i can hold in TCS?

1721


what precautions to be taken while desigining a LT,HT panel. Eg-LT panel PCC panel with ACB installed. HT panel VCB panel with VCB installed. & what is main diffrence betwn IP54 & IP55 construction of panel.

2502


Define branch?

633


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1661


How can we findout the maximum efficiancy of Transformer? At which load?

1612


How Self works in DG set

1421


How to select the earthing transformer,for DELTA TO DELTA TRANSFORMER OR ALTERNATOR SIDE.Pls post your answers and calculation.

1872


why capacitance effect is predominant in underground cable transmission and inductance effect is predominant in over head line transmission?

3199