Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

whats the diff b/w mpcb and mcb?weather it trips on single
phasing or not.

Answer Posted / vinod

MPCB: all the bove full form are correct.
its also an breaker with inbuilt overload protection.
as per the cordination in the panel after contactor OLR is
needed to be provided.if we are using MPCB there is no need
for overload relay.

MCB: Minature circuit breaker.
this limit it is available up to certain breaking
capacity.can be used for lower breaking capacity

Is This Answer Correct ?    6 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the loss of power of transformer 220kv/33kv,63/80mva of % imp12.05 at 80%load

1795


Whether power factor should be high or low? Why?

1065


Define de-sensitivity?

1080


What is the working principle of MIG welding? and its out put Voltage?

3229


can i connect REF and Differencial relay in 1 CT core for transformer protection?

1867


How many points does a Circuit can have?

1892


is it possible to have dc motors on single chip

1775


what is the relation between size of the anteena and wavelenghth of radiated wave

2126


How to calculate earth fault current for 6.6 KV , 50 HZ , 756 Amps , 3000 RPM , 0.8 PF generator

1987


why we used ZNO in Lightning arrester.

1945


How out of step protection relay works?

2345


I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.

2228


what's the simultenous maximum demand (SMD)..what the diffrent MD and SMD?

2406


Difference between control junction box (cjb) and power junction box(pjb)?

4225


is it necessary to earth the rmu before cutting off the transformer winding?if yes why?

1872