Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the meaning of CT 40/5, 100/5 or in HT lines
100/1 ????????

Answer Posted / sripellirajukumar

ya
this is sripellirajukumar


the meaning CT 40/5,100/5,or 110/1 is as follows

HT lines and also any other transmission lines will be
operated with high current ratings..like
100,200,....depends on the requirement of the load..
so we can not measure those high currents directly with low
range ammeters..
so we can use current transformers (CT)in series with the
lines of having high current carrying capacity to measure
the high currents..

CT 100/5 means we can measure 100 amps current by using low
range 5amps ammeter..i.e..here current transformer is acts
as step up transfomer so the current will be less at the
secondary terminals...
that means primary of the ct is connected in series with
the operating line and the secondary of the CT is connected
to the low range ammeter..in CT s turns ratios will be
there...so we can measure high currents very easily with
those CT turns ratio settings...

and above procedure is also same for 40/5,100/1....

thank you.....

Is This Answer Correct ?    49 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

will 1050kva DG set withstand for back charge of 16MVA transformer

1843


how to generator maintenance (A Check, B check,Etc)

2292


How cmd is calculated in case of energy neters

1898


can some one clearly explain why -48 volt DC use in telecom site????

1677


Why is negative feedback invariably preferred in closed loop system?

2301


what is the use of sdf?

2096


Why 9KV surge arrester having 7.65KV of MCOV?

1567


RESPECCTED SIR/MADAM- I AM PRERING FOR SECTION ENGINEER (ELECTRICAL) RRB CHANDIGARH PLEASE SEND ME SOME PREVIOUS YEAR QUESTION PAPER OR MODEL PAPER.MY EXAM IS ON (30- NOVEMBER 2008).I AM VERY THANKFUL TO YOU. FROM- HARENDRA SINGH YADAV

2096


define displacement & magnitude ?

1833


how can calculate 1kva generator running time in 1 liter keroscene

2603


can indirect loading be called as phantom loading?

2182


what happen if the parallel generator phase angle shift by 1 degree in manual mode

2042


How to Calculate KA Rating of Main LT Panel

1741


Why HT 11 KV Slipring Motors are connected in star ?

2217


write a program that prints prime numbers from 1-20 in digonal form

1993