if we use fuse in neutral what will happen?

Answer Posted / saurabh chaubal

Firstly by electrical electricity board it is said so and if
we put fuse in neutral then if bcoz of over current the fuse
will blow out in neutral. But the person who is touchin the
live conductor will get a shock.... As there is no
protection there...

Is This Answer Correct ?    7 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how can i apilly for electrical c licencese.sir,i completed B.Tech in electrical & electronics engineering in 201onot working any company

1592


critically criticize the application of ring main unit in power system

1106


what is the maintaining Cf in UPS.

1840


I want to make street light with solar system ... What may I do for procedure and how much of estimation for each material ... If any one knows guide me and inform this id : aravindd7@gmail.com

1451


What do you mean by dependent and independent voltage sources?

706






can any tell me why slope 40% and 80% is calculated in differential protection?

1525


If you have an earth with pilecap then your resistance is really low. why and how?

1524


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1797


How to measure size of cable on a given load

1483


What is difference between insulating medium and fault current interruption medium in a switching device.

1235


WHY IS THE EARTH FAULT CURRENT ALWAYS LESS THAN THE NORMAL CURRENT??

1829


What current flows in the transformer primary when its secondary is open?

750


how to setting Load amps tripping time and extra settings for load Transformer protection relay with RMU panel using C&S model relay..?

693


What is DTR erection?

3707


i want to know that what is the eligibility critaria for ongc exam?

2663