Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Wat wil happen if Transformer is operated at 100 HZ
Frequency?

Answer Posted / phkhatri

Follwing series of action will occur when 100Hz power is
applied to 50Hz transformer.
1) Core gets saturated
2) No,load losses increases and Temp. too goes up
3) Output voltage cannot be predicted as the core is
totally saturated.
4) Heating continous and gradually damages the core
5) This is followed by heating up of the oil and thus
cooling temperature goes down sharply.

Is This Answer Correct ?    15 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

As i want some model question paper in basic computer science and history please send me immediately sir

1945


How to calculate Grid rotor resistance(GRR) losses in slip ring induction motor?

4330


How to prepare electrical preventive maintenance plan & shedule of machine tools in manufacturing unit.

2230


how to select the double earth conductor if 21A full load?

2109


What Normal(Tangent) towers and Tension(Cut-point) Towers?

6287


Control cables in S's will carry 1000v which is AC R DC? Pls answer meĀ 

2196


I want formula to calculate current loss with distance in km.I searched many sites but didn't right answer.Plz reply me

2123


in HT service 3ph 4 wire service Y-phase voltage shows zero . whether it is meter fault? or what be the reason ? if y-ph voltage zero ,can current is recorded? reasons for failure?

1987


What is mean by Sensitive Earth fault & what are the effects

4608


If the feeder rating is 7.5 kw or 10 HP star-delta feeder, MCCB is taken as 63 a, contactors-32 a, how much will be the OLR rating or which range OLR should be considered when we concern about type-2 coordination?

2362


How to calibrate or test an LT Air Circuit breaker 440 volts, 35 KA, 800 Amps ?

2653


what is the difference between interconnection and intraconnections in the circuit diagrams

8466


If we connect a motor and generator together (I mean that the generator gives the motor electricity and the motor gives the generator movement) regardless the losses. Will the generator still generate and the motor still move?

2328


How we can defined theecopper cable size if we know the aluminium cable size?

1928


how is the incoming cable size calculated for a given current rating of a panel??

1988