why the generating voltage in India is 11kV or why is it be
transmitted as multiples of 11
Answer Posted / chandru_williams
I srrongly disagree with Kavitha. Insulators are made only
for the volateg ratings produced ( 11KV). The actual reason
is as follows.
1. When an alternator generates voltage, its rms value is
given by 4.4*f*$*t, where $ is value of total flux per
pole. So we can see all the voltages are made inevitably
multiple of this value (1.1, which is the form factor of
ac wave). Also it provides us the best economic
construction of step up and step down transformers.
2. We always use a multiple of 1.11 bcoz for a pure sine
wave the FORM FACTOR is the ratio of rms value of voltage
or
current with the avg. value of voltage or current and for
pure sine wave rms value of current is Imax/root '2' and
avg. value is 2Imax/pie. and which comes out to be 1.11 so
we cant have a combination of other then a multiple of 1.11.
| Is This Answer Correct ? | 20 Yes | 9 No |
Post New Answer View All Answers
What will happen if the armature resistance is in minimum position and the field resistance is in maximum position while starting the motor
Why is tan-delta test and capacitor measurement done on alternator?
What are the function of different components of servo motor?
i need to now what will be the cable size to the following load, transformer to distribution panel distance 110m, load 1000kw, voltage 400v, pf 0.85, permissible voltage drop 2.0%, overhead line, atmospheric temperature 35 degree c.
As we know diode work on both negative and positive but converting ac into DC we have to given a/c from negative of diode or positive side.please give me answer.
what is the difference between fault current ant short circuit current?
What is icu and ics in Acb and how many time icu or ics passes from breaker?
The magnitude of sum of two sinusoidal av voltage is equal to 230 volt.the magnitude of each individual voltage is also equal to 230 volt.what must be the phase difference between voltages?
What are merits & De-merits of State-Space Method? What is series programming, parallel programming, general programming & direct programming ? And, difference between these programmings Techniques ?
What is fault clearing time for Current Limiting Moulded Case Circuit Breaker?.
How to know the following data of synchronous generator 1. D-Axis Unsaturated Reactance 2. D-Axis Unsaturated Transient Reactance 3. D-Axis Unsaturated Sub - Transient Reactance
What is an automatic controller?
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
How much minimum insulation required between 11kv/3.3kv transformer windings?
How to reduce -234126219.6403 MVAr generation and by what?