Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Ten Delta Test ?

Answer Posted / natarajanramkumar

Tan-Delta also called loss angle OR Dissipation factor
testing is a diagnositic method of testing cables to
determine the quality of the cable insulation.This is done
to try to predict the remaining life expectancy and in
order to prioritize cable replacement and/or injection.It
is also useful for determining what other tests may be
worthwhile.

Is This Answer Correct ?    29 Yes 20 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1600kva capacity Transformers how the bucholz relay,Oil temperature,winding,surge relay relays setting are to be done

1908


diff b/w elcb and rccb

2300


i m in need of current rating chart of heavy duty pvc/xlpe, cu/al cables. can somebody provide me? if yes, plz send me at ashish_patel111@yahoo.com

2016


How to test the vector group of a Yd11 transformer? what are the relations to be checked between various vectors to confirm this vector group?

4472


why effective resistance should be more than static resistance in transmission line?

2102


Why can't we parallel the secondary circuits of two voltage transformers?

1535


Why Ac Systems Are Preferred Over Dc Systems?

1305


What is the formula for calculating impedance of transformers connected parallel at fault level 50KA?

2089


what topics we have to concentrate for power grid et.written test.and tell what to read for english synonyms and antonyms.

1953


define reflection method?

1949


why we are not giving the zone 1 trip command to the master trip relay

1732


what is meant by loss of field in a DC motor? how a universal motor works?

1850


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2151


What is an ideal transformer?

1175


What is ferro-resonance in electrical system? Why it occurs and what are measures to prevent it?

2235