Answer Posted / natarajanramkumar
Tan-Delta also called loss angle OR Dissipation factor
testing is a diagnositic method of testing cables to
determine the quality of the cable insulation.This is done
to try to predict the remaining life expectancy and in
order to prioritize cable replacement and/or injection.It
is also useful for determining what other tests may be
worthwhile.
| Is This Answer Correct ? | 29 Yes | 20 No |
Post New Answer View All Answers
What is the relationship between voltage,current & frequency?
why would the rotor rotate at sub synchronous speed against the direction of rotating flux when d rotor of 3 phase IM is connected to 3 phase balanced supply and the stator windings are shortcircuited ??
Why L.T.Cable voltage rating is 1.1kV,where as system voltage is 0.415kV?
EXPLAIN THE WORKING OF SERIES REACTOR IN HT CAPACITOR BANKS (FOR VOLTAGES & CURRENTS)
How to select batteries required for ups and the inverter if we Known load? And how AH is selected of battery?
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks
Can you explain about Restricited earth fault protection scheme
what is the IS foe lightning arrester?
can i use the six sigma method which is used in management area, in state estimation of power systems?
what are the standard IR values should be of R-E, Y-E, B-E, R-Y, Y-B, B-R of VCB in closed condition and in open condition for 500KVA & 1000KVA transformers. and what is the acceptable range when tested by 5000V megger.
A power transformer 4MVA/11KV/0.415Kv has been out of use in 12years. what maintenance actions/test need to be carried out before energizing.
In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)
how does grading rings & spacers in transmission line works? Working Principle?
What does the term supermesh means?
why power factor is important?