when the size of the cable used for the ht voltage is 300sqmm
then what is the size of the conductor of each phase
Answer Posted / prabhakar tiwari
300sqm each conductor because size of con.will same only
kv rating vary always 11,22,33,66kv kv decide insulation
level of cable cond.carry same current.
Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?
What will happened if the neutral of secondary of Xformer ( Star point) Note it's above KVA rated Xformer
PLEASE TELL ME ABOUT QUESTION PAPER OF UPCL ENTERENCE EXAM.
What will happen if i used 11KV earth ht kit to 11 KV / 11 KV cable termination?
A parallel flow heat exchanger will perform better than a counter flow heat exchanger. State if the statement is true or false.
What does a Bode plot tell you?
how line turns ratio changes in 3 phase with change in connection
what is meant by flywheel and its role in retardation test
A jet of fluid strikes a plate What was the force required to counter it?
How to check the cable fault / hv test of transformer cable.
What is precision of a measurement?
how are reversing the direction of rotation of dc motor
Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING) I O (current operating)?