when the size of the cable used for the ht voltage is 300sqmm
then what is the size of the conductor of each phase

Answer Posted / prabhakar tiwari

300sqm each conductor because size of con.will same only
kv rating vary always 11,22,33,66kv kv decide insulation
level of cable cond.carry same current.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1266


What will happened if the neutral of secondary of Xformer ( Star point) Note it's above KVA rated Xformer

1425


PLEASE TELL ME ABOUT QUESTION PAPER OF UPCL ENTERENCE EXAM.

7052


What will happen if i used 11KV earth ht kit to 11 KV / 11 KV cable termination?

1002


A parallel flow heat exchanger will perform better than a counter flow heat exchanger. State if the statement is true or false.

781






What does a Bode plot tell you?

824


how line turns ratio changes in 3 phase with change in connection

1428


what is meant by flywheel and its role in retardation test

1978


A jet of fluid strikes a plate What was the force required to counter it?

1473


How to check the cable fault / hv test of transformer cable.

1418


What is precision of a measurement?

685


how are reversing the direction of rotation of dc motor

1277


Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT

2139


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1668


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING) I O (current operating)?

1753