1. What is the difference between ac induction motor
and ac synchronous motor?
Answer Posted / stanley electrician
Above answers are ok.
If you want more, get diploma 4th sem Electrical machines 2
book.
You have get clear knowledge about the motor
| Is This Answer Correct ? | 14 Yes | 14 No |
Post New Answer View All Answers
What is Annunciation?
What do you mean by a voltage transformer?
WHAT IS DIFFERENCE BETWEEN CAPACITOR AND CAPACITANCE?
can we conduct the swineburne's test on a dc series motor? why?
We have two APFC panels in same station. I need how to connect CT in two APFC panels.can we take one CT in series connection or two separate CTs.
Give details on how you intend to handle a challenging position you are posted to manage unexpectedly as a company staff?
What is minimum permicible value of leackage current for LT Panle when applying voltage up to 3 KV for 5 Minuits?
what is formula to cal cute earth pit numbers and size of earth strip used in earthing?
If an electrical component has a positive temperature coefficient, how come such components have high power losses due to heat if current decreases when resistance increases? assuming power given by I^2*R whereby the Resistance is infinite.
Why corona leads to production of Ozone and glow of the color VOILET?
What are the causes of unbalanced current on 34.5kv feeder Ia=0.05,Ib= 0.25, Ic=0.15 and In=0.27 prior to tripping current are balance?
why do you add the load short circuit impedance when considering short circuit amperage. It seems that you should only consider supply. If you need to consider loads and you don't know what loads are to be added , what would be a good sub-transient reactance rating for the loads?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what is effect of 5amp fuse on 2mva pry protection of transformer
How can we calculate cable size in Low voltage & high voltage