PID controller is used for which type of compensation……
a) lead comp. b) lag com. c) lead lag com.
Answer Posted / krishna
LEAD AND LAG COMPENSATION IT CONSISTS OF THREE ACTIONS
| Is This Answer Correct ? | 15 Yes | 0 No |
Post New Answer View All Answers
Which type of diaphragm use in costic line, dm water line, natural gas line, oil line?
how u choose thermowell lenght n pnumatic C/v size?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
How is flow measured in square root?
how do i tune dearator pr control valve using PID. we set the set point is 0.6kg/cm2 now i want 0.5 to 0.7kg/cm2 limits so what should i give p,i,d values. then pls explain how do set pid values for control valve tuning?
In VVVF DRIVES VOLTAGE IS ALSO VARY WITH THE FREQUENCY. HOW? WHAT IS THE DIRECT FORMULA RELATING THESE TWO.
Hi, Is there any smart plant instrumentation design training institute in Bangalore?
Draw a complete P&ID of a flow suction tank indicating all control & protection equipment. Indicate all its inlets and outlets. Explain the controls for this system
can any one explain in which term we are flow flow is it volumetric r is it mass? and y
what is insdustrial vibration.who it works. give atleast 2 types of insdustrial vibration
if my flow is 20000 m3/h than which range of DPT i have to use????
What are different types of valves?
What is the difference between uv and ir scanners? and what is the workig principle of both
what is the vital subject for scoring bhel exam&what is the question pattern
what is performance test.need defination