Why Lightning arrester used? Can we use piece of iron as a
core material of transformer, if No, why? In CRGOSS
material what is meaning of cold rolled grain oriented? Why
Impegrenation of Transformer is done? Properties of
Insulator? what is phase angle? Testing of transformers
(Routine & Monthly)?
Answer Posted / deepak
lightning arrestor is a highly pointed device , which can
make the ehv coming from the lightning to split into
positive and negative ions...this ions are absorbed by the
carriers and they are byepassed to the earth ,which is
basically a zero potential.we cannot use iron because eddy
current produced in the iron will be very high .
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
calculate external resistance values to add to the rotor of a slip ring induction motor. STATOR- 415 V, 3 phase delta, 1100 A, 50 Hz, 1490 rpm, pf 0,86 ROTOR - 660 V, 590 A, 50 Hz. STATOR current at each steps STEP1-600A,STEP2- 800A,STEP3-1000A,STEP4-1100A.
sir please tel me how calucalte kwh if home taken load 30ams how maney kwh taken per day.and 3phase motor 5hp per hars how maney load teken and how mach kwh and forward me to electrical table for calicalte kwh and kvr and kvah
How many types of faults are there in 3 phase power system?
how to generator maintenance (A Check, B check,Etc)
The SFC of an engine is 0.25 kg/kW hr. when the fuel used has a calorific value of 36000 kJ/kg. the thermal efficiency of the engine is
why does make gain margin and phase margin on same plot.?
Can you explain about Restricited earth fault protection scheme
how we decide the require size is this for a known current at fuu load?
Vaccum circuit breaker
In constant power region of 3-phase IM torque-speed characteristics, if frequency increases flux A does not alter B decreases C increases D none of above
Pl. share your experience about industrial-electronics repair of machine tool.
What is the lifetime of a Thyristor? Is there a recommended lifetime for thyristors after which they should be replaced?
what is the effect of connecting three phase supply lines to three phase auto transformer output terminals through a fuse of 10Amp and a circuit breaker (MCB). Is this connection permanently destroy the transformer?
How are load losses and no-load losses measured at site in a DG set?
Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT