Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why one can experience electrical Shock due to Voltage or
Current?? or both voltage or current??

Answer Posted / smita

EXPERIENCE SHOCK BECAUSE IF THERE IS ANY POENTIAL
DIFFERENCE THEN CURRENT WILL FLOW AND SUPPOESE HUMAN BODY
(WHICH HAS SOME RESISTENCE) IS IN CONTACT THEN IT GIVES LOW
RESISTENCE PATH TO IT AND THE PERSON WILL GET SHOCK

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If we have use two power cable for incomer, that time how many use cbct for earth leakage protection? 1 or 2 if 1 way? If 2 way?

2060


which mm cable should be used for 1.hp immersible pump motor for the distance of 330 metres?

1668


how technical is calculated in 11kv line and lt line

1974


Can any one provide the inspection procedure of MIMIC for VFD panel? Details: If someone wants to have a mimic in the VFD panel what are inputs considered for the mimic(like on,off,trip) whether we are able to add speed variation in the mimic(if so how can we get) and what are the parameters to be checked in the MIMIC during inspection?

2148


Mention the disadvantages of low power factor?

1072


what is the safety of voltage power transformer(2250KVA0

1930


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity?

1930


How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?

2710


The capacitive reactance of a capacitor of 1/(2(PI)) F at 10^3 H is

1788


How servo stabilizer works.

2063


for hipot test on 33kV busbar, we will test on 70 kV or 56kV, what is the acceptable leackage current?

1100


What is different bewteen low or high impedance busbar protection scheme

4068


regarding safety what would u consider the most important rules to observe when inspecting electrical equipment?

1990


I have a relay contact rated at 220v dc which is supplied with a 24vdc from the panel,for it to trip the dampers(24vdc).What if the application of the relay changes so that it should work at its rated 220vdc then will it work at 24vdc supply given or any other consideration needs to be taken .....

2017


hi pal, i am vengatesh from tamilnadu(chidambaram),i have called for the written test for the post of jr executive(ELECTRICAL) of AAI ,I dont know about the question paper pattern,so any kindly help me to face the examination,post me the model question papers and some tips to write my examination to (vengi.annadurai@gmail.com)

1837