Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In a three phase transformer(delta/star connected)when i
touch one end of the bulb in any one phase and other end to
earth..will the bulb glow or not..if not why?..i'm touching
the bulb in star connected side...

Answer Posted / bala123

Definetely the Bulb will glow,because essential points for
glow the lamp can get via your body i.e phase and
neutral,hence the lamp will glow.Incase if not,i think (not
sure) your body may have higher ohmic resistace.

Is This Answer Correct ?    2 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the protections for safe running of electric generator?

2251


Advantages of using generator circuit breaker (GCB) scheme in a power station ?

5274


what are carbondioxide and dcp used in fire extinguishers

2049


we all know voltage is a force(emf), and the force always devides if 2 or more than2 loads are there but why does the voltage remains same is parallel, it must devide na ???

1983


How to decide the size of the capacitor for a single phase induction motor say 2 HP ??

2220


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2146


what is 30-phase of transformer

2290


main difference between ac and dc?

1702


how is the incoming cable size calculated for a given current rating of a panel??

1925


sir i applied for hpcl(electrical).i want to know from which subjects most of the technical que will b asked.and pattern of the written test.pls help me

1938


when ac current flows thru d coil of a contactr,it energizes,magnetic field attracts d contact of the coil...nw wont dt ac current in d contct induce current back on to d coil thru mutual inductance leading to high currnt in d coil

1704


how to calculate maximum current

2321


Please clarify 1. Icw: rated short circuit working withstand capacity 2. Icu: Rated ultimate breaking capacity 3. Ics: Rated service short circut withstand capacity 4. other specification of ACB

2728


3 phase induction motor connection star or delta while using ac drive motor is .75 to 5.5 kw

1958


what is cathodic protection and why it use in industries?

2281