Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In a three phase transformer(delta/star connected)when i
touch one end of the bulb in any one phase and other end to
earth..will the bulb glow or not..if not why?..i'm touching
the bulb in star connected side...

Answer Posted / jagjeet

If it is distribution transformer and having 440 line to
line voltage , definately bulb should glow because the
bulb has been connected via earth i.e. 220 volts ( Phase &
Earth)

Is This Answer Correct ?    18 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the general system requirement of alternator?

1841


What are your personal skills and abilities for such a Master Course and your possible preparation to undertake this course?

2035


it is in our knowledge tht right plug of supply of residential suppy system is phase n other is neutral...howevr the battery charger of mobile works in both ways...i mean it is not restricted in only one direction.ny of the holder of charger can hav phase .so y is it not lik tht phase of supply must b connected 2 phase of charger...?

2015


how electical engineer is related to apsrtc (general) post? if they ask a question in interview as why did u choose this job what shd be answer

2182


How much load can take a 16 mm aluminum cable 3 phase

1747


What is the difference between circuit breaker and isolator

1242


how many parameters can integrate with fire alarm basically ?

1953


What are the advantages and disadvantages of short-pitched winding?

1085


The transmission does not have options: a)Partition noise b) Flicker noise c) resistance d) Short noise and reason

2433


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2014


how i can calculate the size for fire cable

2008


What is referred to the electron in the outer orbit?

1144


How we can determine short circuiting current any plant and for example a plant which power generation is 415 volts and plant load is 500 kw.

1984


An impedance of 100 ohms resistance and an unknown inductance is connected across the capacitor. The resulting impedance is a pure resistance of 500 ohms ifω = 10^5 rad/sec. calculate the values of inductor and capacitor.

1415


The efficiency of a 100kva transformer is 0.98 at full load as well as half load , for this transformer what is the Copper loss at full load ?

2322