WHY TRANSFORMERS ARE RATED IN 11KV 22KV 33KV Instead off
10kv 20kv 30kv
Answer Posted / suneetha
this is due to form factor
rms value of induced emf= form factor * average value
form factor is calculated as 1.11
so the ratings are usually expressed in multiples of 11
Is This Answer Correct ? | 72 Yes | 11 No |
Post New Answer View All Answers
plz explain the auot-reclosing circuit in electrical engineeing
1)How much current can a 3-1/2 core 100 mm wire carry? 2)What are the special cables required for explosion proof wiring? 3)In case you do not have coal and salt for earthing, how can you achieve good temporary earthing? 4)One horse power single phase motor is more likely to get hot than a one horse power 3 phase motor. Is it true or false, if true why? 5)What are the different types of soft starters for large motors?please explain?
State the methods of improving power factor?
List examples of voltage source?
High speed earth switch operation with diagram
According to conduit size which size wiring & how many wires can we provide wires in conduit & how can we select conduit size accordingly?
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
i want use the cable size 16cx4 core aluminium usege watts 240x2000w this cable size is correct?
DEAR SIR,I GOT THE CALL LETTER FROM RRB, SECUNDERABD AS A JE-II SO PLEASE PROVIDE ME SOME MODEL QUESTION AND ANSWER PAPERS AND LAST YEAR QUESTION PAPERS
How many types of electrical earthing are there?
how u select control transformer for a mccb panels or any panels?for expample we hav 440 volts maim supply and control volts is 230v?
What is bridge rectifier and explain with details
10 Mtr Hight of Lighting Arrestar how much area coverd??
I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.
How many points does a Circuit can have?