what are the main parts of DG? explian thier functions?
Answer Posted / kalidass
A normal DG (Diesel Generator ) having two parts.
1. Engine
2. Alternator.
The engine is a pimemover of the alternator. The engine is
started by using DC start motor.Following attachments are
fitted with engine.
1.Self start arrengemnt.
2.Radiator arrengment.
3.Air filter.
4.Lub oil arrengement.
The second one is alternator which is convert mechanical
power into electrical power.
Alternator having following arrengemts.
1.AVR (Automatic Voltage Regulator)
2.Startor winding
3.Field winding
4.Rectifier
Normally the DG capacity mensioned as in KVA raring.
| Is This Answer Correct ? | 389 Yes | 23 No |
Post New Answer View All Answers
in general it is observed in power stations, the tertiary winding is used in higher rating Y-Y auto transformer but not in Y-Y power transformer. is the tertiary winding is compulsory then why it is not using in power transformerÂ
state the working principle of incondenscent tube?
How to calculate multiplication factor in kva example 500kva ans pls ?
what is laser diodes?
what is motor capacity of 80TR chiller? and also say what is the formula related temperature, motor capacity, TR?
it is possible to measurement of tension of slipring induction motor(SRIM)carbon brushes, any maesuring instruments are available in the markets.
Dear sir, I completed DECE In the year 1995.Now i am working in a private company from last 10 years as an Electrical supervisor.The company having a 1000 KVA transformer.Now i try to apply "C" Licence. I am eligible or not.If not eligible,pls give solution.
How will A Medium voltage circuit breaker(11 kV voltage level) operate under short circuit fault condition whether It is having short circuit release like Low voltage circuit breaker or relay should be given?
While HT line put on to activate ACB in low tention panel VCB tripping instantly.why it happens
what is the difference between circular wdg & ractangular wdg?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
HOW TO REDUCE POWER PLANT AUXILIARY POWER CONSUMPTION?
How to decide DO set rating of Transformer?
what a function diesel generetaor turbo charger & turbo charger is more heated explain reason ?
I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?